Contents
- How the KL MZ works
- Before you start
- Quick start in ten steps
- Mounting and connecting
- Joining your Wi-Fi network
- Understanding the detection area
- Creating zones
- Setting the boundary
- Teaching the room, boundary and zones
- Settings and LED
- Room climate and siren
- Wi-Fi options
- Home Assistant and MQTT
- Remote access and web app
- Backup, update, reset
- If something does not work
- Technical data
- Safety, conformity, disposal
1. How the KL MZ works
The KL MZ presence sensor detects motion and presence, even when someone is sitting still or asleep. Its 60 GHz radar (FMCW) registers the smallest movements such as breathing, which makes it far more sensitive than an infrared motion detector. It detects motion up to about 6 m and calm presence up to about 4 m.
It also shows where people are in the room: up to four people at the same time, provided they are far enough apart. You divide the room into zones, as a rectangle or a freely shaped polygon, drawn or taught on site. In total 13 zones are available: 4 detection zones, 4 stay zones, 4 interference zones and 1 boundary.
It also measures brightness, temperature, humidity and air pressure, and has a siren with 15 sounds and a switching signal output. It runs on your Wi-Fi network and you operate it in the browser. The readings go via MQTT to Home Assistant and other smart home systems, or instead to your phone through Senvolon remote access.
What affects positioning: Reflections off walls, furniture and glass, materials that absorb radar waves, other electronic devices nearby, and rooms with many obstacles or moving objects. Choose the mounting location with a clear line of sight into the room, without direct reflections and away from other electronic devices and reflective surfaces. If two people stand very close together or one hides the other from the sensor's point of view, it cannot detect them separately.
More about the device on the KL MZ presence sensor product page, examples of use at Room monitoring with the presence sensor.
2. Before you start
You need:
- The name and password of your Wi-Fi network. The presence sensor uses the 2.4 GHz band.
- A USB power supply with 5 V DC and 2 A to 3 A (max. 15 W), USB-A output, limited power source (LPS) and CE marking. The power supply is not included, the USB-A to USB-C cable is.
- A smartphone, tablet or computer with a web browser. You do not need an app.
Safety notes: Read these notes before putting the device into operation. The presence sensor is designed exclusively for indoor use for the purpose stated in this manual; the housing is not protected against water. The ambient temperature must be between 0 °C and 40 °C. Route all cables so that they are not damaged or crushed. Keep a distance of at least 20 cm from people during operation. Modifications to the device are not permitted.
You can switch the web interface to English under “System”.
3. Quick start in ten steps
In this order you get to a ready-to-use presence sensor fastest. You can fine-tune everything afterwards at any time.
- Prepare. Have the power supply and a smartphone or computer ready. At first, put the presence sensor into operation only temporarily.
- Connect to Wi-Fi. Connect to the access point of the presence sensor, enter your Wi-Fi network and note the IP address shown (Chapter 5). Then set the language under “System” and switch on the protection with “Login” and “Password”. Also change the default password of the access point (Chapter 12).
- Choose the mounting location and mount the sensor. On a wall or in a corner of the room at a height of 1.50 to 2.00 m, or on the ceiling. The corner is often the best choice: the sensor looks diagonally into the room and, with its beam angle of ±60°, covers almost all of it (Chapter 4).
- Make the basic settings. Under “Settings”, set “Installation” and, if needed, “Reflect horizontal”, and do so before you create zones. Changing the installation type later resets all zones. For setup, set “Room timeout” to a few seconds so that you see every change immediately (Chapter 10).
- Learn the room. Under “Zones”, in the “Teach room / boundary / zone” section, choose the “Room” and start “Learn room”. You then have 20 seconds to leave the room. The presence sensor creates up to four interference zones for sources of interference such as a ventilation fan (Learn room).
- Walk through the detection area. Walk through the whole room several times on your own, along the walls and into the corners as well. The gray area shows what has been covered so far (Chapter 6). If people appear where nobody is, for example behind glass, in front of a mirror or in the next room, set a boundary. If people keep appearing briefly in the room itself, switch on the “Ghost filter”.
- Create detection zones. As a rectangle or polygon, drawn or taught on site (Chapter 7). Give them meaningful names under “Zone names” before you integrate the presence sensor into other systems. Then walk through the zones and check that they change color when you enter them.
- Add stay zones. Where people sit or lie still for longer, for example a seat, a bed or a desk. If needed, bind them to the matching detection zone and choose a stay time.
- Set the timeout. Set the “Room timeout” for normal operation. If a zone needs a different timeout, switch on “Timeout per zone” and set it at the zone.
- Back up the settings. Under “System”, download the configuration and keep the file “config.json”. You load it again under “Update” (Chapter 15). For Home Assistant and access while you are away: MQTT and remote access.
4. Mounting and connecting
Before mounting for good, familiarize yourself with the detection area (Chapter 6) and check the location temporarily first. Make sure the Wi-Fi signal at the mounting location is strong enough.
With the room planner you can see in advance which area the presence sensor covers from your desired location. When a ceiling, wall or room corner is the better choice is explained in the article Mounting a presence sensor: ceiling, wall or room corner?
On a wall or in a corner

Mount the presence sensor at a height of 1.50 to 2.00 m on the wall or in a room corner. In the corner it looks diagonally into the room and often covers it more completely. Power can be supplied from below or from above. If it comes from above, switch on “Reflect horizontal” under “Settings”.
Higher than 2.00 m, for example directly below the ceiling: tilt the presence sensor slightly downwards so that it looks at chest height towards the opposite side of the room. Do not tilt it more than necessary, otherwise the range at the far end drops. “Installation” stays set to “Wall / corner”. In this case create the boundary and zones by teaching them. If you change the tilt later, teach the boundary and zones again.
For the room corner and tilting there is the corner and wall mount: it aims the presence sensor diagonally into the room in a corner, and straight ahead and slightly downward on a smooth wall.
On the ceiling

The higher the ceiling, the larger the area covered (2.5 m in the picture). Set “Installation” to “Ceiling” under “Settings”. Reflecting is possible here as well. The radar sensor sits behind the closed plastic cover and radiates into the room.
Open the housing and fasten it

- Remove the three hexagon socket screws and carefully lift off the cover.
- Screw the housing to the wall or ceiling with two screws.
- If you use the JST PH 2.0 connector inside, connect it now and lead the cable out through the rear opening, as well as the switching signal output.
- Put the cover back on and screw it tight.
- For power over USB-C, connect the presence sensor to the power supply with the enclosed cable.
Connections inside
Inside there is a 4-pin JST PH 2.0 socket. You use it to supply the presence sensor with 5 V, and it provides the switching signal when presence is detected.
| Label | Meaning |
|---|---|
| SIG | Signal output (0 V = no presence, 3.3 V = presence) |
| 3V3 | 3.3 V output |
| GND | Ground |
| 5V | 5 V input |
5. Joining your Wi-Fi network
- Have your Wi-Fi details ready. Name (SSID) and password of your Wi-Fi network.
- Connect to the presence sensor. It opens a Wi-Fi network of its own named “PresenceSensor-xxxxxx”. Connect your smartphone, tablet or computer to it. The default password is “12345678”.
-
Open the interface. In the browser, open
http://192.168.4.1/wifi. If the page does not appear, check that you are still connected to the Wi-Fi network of the presence sensor, and switch off mobile data on your smartphone or tablet. - Enter your Wi-Fi network. Select your network or enter it under “Network name (SSID)”, and enter the Wi-Fi key under “Password”. Under “Hostname” give the presence sensor a name. You can leave the fields under “More” as they are for now. Tap “Save” and wait a moment.
- Check the connection. If it worked, the IP address of the presence sensor is shown at the bottom of the page. Note it down. Connect your device to your own Wi-Fi network again and open the IP address in the browser.

Forgot the IP address? It is also shown in the interface of your router, or you can search for the name of the presence sensor with a network scanner app. If your router supports names, you can also reach it at http://hostname, on a FRITZ!Box at http://hostname.fritz.box. If it is available neither in your Wi-Fi network nor through its own Wi-Fi network, disconnect it briefly from the power.
6. Understanding the detection area

As delivered, “Installation” is set to “Wall / corner”. If the presence sensor hangs on the ceiling, switch to “Ceiling” under “Settings”. The room view adapts to the installation type.
- Semicircles show the distance to the sensor in meters.
- The gray area is the area where someone has been detected so far. Walk through the room several times, the area grows by itself as you do. If the room is larger than this area, detection ends at its edge. If the coverage is not sufficient, choose a different mounting location.
- The area figure at the top left shows the size of the gray area; as soon as a boundary is set, it shows the size of the boundary.
- Detected people appear as a symbol and the frame turns pink. If someone is in a detection zone, the zone changes color too. Up to four people are shown at the same time.
While the gray area is built up for the first time, the presence sensor sometimes shows too many people, or the symbols jump. If the room is not covered well enough, choose a different mounting location.
7. Creating zones
Zones divide up the room, and presence is reported separately for each zone. A bathroom, for example, can be divided into washbasin, toilet and shower. Tap “Zones” to open the menu and the editing mode. Tapping “Zones” again ends it.

There are three kinds, four of each:
- Detection zones are the areas in which people are detected and reported.
- Stay zones are areas in which calm presence is preferably measured, for example at a seat.
- Interference zones are areas in which nothing is to be detected, for example at a ventilation fan.
You switch each zone on and off with its switch. Then you move it by dragging and change its size. Zones may overlap or lie inside one another. If one zone lies on top of another, hide the upper one with the square next to its switch. You set the names under “Zone names”.
Rectangle or polygon
Detection zones can be a rectangle or a polygon with up to eight corners. The symbol in front of the hide square shows the shape, tapping it switches it. A polygon then becomes the rectangle that encloses it.
- You change a rectangle with the handles at its corners and edges.
- In a polygon you move each corner individually. The “+” in the middle of an edge inserts a corner. Tap a corner and then its “X” to delete it. A polygon has at least three corners and its edges must not cross. An invalid shape jumps back to the last valid one.
- You move the whole zone by dragging it by its area. On a touchscreen, hold the area for a moment first, until the zone is highlighted.
Stay and interference zones are always rectangles. With “-” and “+” at the top right you reduce or enlarge the view.
Timeout per zone
If “Timeout per zone” is switched on under “Settings”, every detection zone has a second row “Timeout”. It determines how long the zone stays occupied after nobody is there any more: from “No delay” through 1 second up to 10 minutes. “No delay” frees the zone immediately. “As room” takes the “Room timeout” from the settings, whose value is shown in brackets behind it. The switch is off as delivered, and every zone then holds as long as the room.
Stay zones
A stay zone has an adjustable stay time: this is how long the presence sensor waits before it reports that a person is no longer detected. Brief interruptions of detection are bridged this way. Place stay zones where people actually stay, for example on a seat, a bed or a desk, and if possible not at the edge of the detection area, where people leave it.
As stay zones often match detection zones, you can bind the two together. The detection zone then also gets the stay time. The bound stay zone is no longer shown as a zone of its own and cannot be switched off. To delete it, release the binding first. If the bound detection zone is a polygon, the stay time applies within its enclosing rectangle. It is shown dashed in the color of the zone and can be shown or hidden.
Interference zones
You draw interference zones yourself or let the presence sensor create them: with Learn room. “Reset detection area” deletes the gray area, after which it builds up again by itself.
8. Setting the boundary
Radar waves are reflected by glass, mirrors and smooth surfaces. The presence sensor may then show people where nobody is, for example behind a window pane or in the next room. With the boundary you define where the room ends. Targets outside it are shown in gray and are not evaluated: they occupy no zone and trigger neither presence nor the siren.

The boundary is the dashed line. It stays fixed until you change it. You edit it under “Zones” in the “Boundary” section: when switched on, the switch creates a rectangle around all active detection zones and opens it for editing straight away. Later you start that with “Edit”. A bar with “Done” and “Cancel” then appears at the bottom. The boundary can have up to 16 corners.

Do not set the boundary too tight: if someone standing in the room is shown in gray, the boundary is too far inside at that point.
9. Teaching the room, boundary and zones
Instead of drawing, you can teach on site: the presence sensor records your position and creates the zone from it. You find this under “Zones” in the topmost section “Teach room / boundary / zone”. First choose the room, the boundary or the zone under “Area” and then start the method. Only the buttons that suit the chosen area are active. Bound stay zones are not offered, because they follow their detection zone.

Learn room
With this the presence sensor creates interference zones for sources of interference, such as a curtain in front of an open window or a fan.
- Choose the “Room” as the “Area”.
- Use the slider to set the “Learning time” (60 seconds as delivered).
- Tap “Learn room”. After the prompt you have 20 seconds to leave the room.
- Stay outside during the learning time, otherwise a person is learned as a source of interference too. The bar at the bottom counts down and shows at the end how many of the four interference zones are set.
Setting a zone by corners
For detection zones with clear edges. Only one person may be in the room while teaching. A bar appears at the bottom with the name of the zone, a note on the next step and the buttons.

- Stand at the first corner of the zone you want and tap “Set point”. Stay where you are until the corner is shown with a number.
- Walk to all corners in this way, at least three, at most eight.
- “Undo last” removes the corner that was set last, “Done” stores the zone, “Cancel” ends without changing anything.
If the position does not settle, the point is accepted anyway after 10 seconds at the latest. If nobody, or more than one person, is detected, the point is dropped and you set it again.
Teaching the boundary
Choose the “Boundary” as the “Area” and tap “Set corners”. Stand in each corner of the room and set a point there: up to 16 with the sensor on the ceiling, up to 14 with it on a wall. The boundary is placed 30 cm beyond the points, so that somebody close to the wall still counts.
With the sensor on a wall, the bar first asks where the sensor hangs:
- “On a wall”: The sensor does not see the corners beside it. Start at a side wall near the sensor, walk the room corners and end at the other side wall. The boundary is closed towards the sensor's wall; two corners at the opposite wall are enough.
- “In a corner”: Set a point in every room corner except the sensor's, once round the room. The boundary is closed along both walls to the sensor, so that nothing behind the walls counts.
Learn dwell
For areas in which people stay, such as a seat or a desk. Works for detection and stay zones, not for the boundary.

- Use the “Learning time” slider to set how long positions are collected.
- Tap “Learn dwell”, go to the place you want and tap “Start”.
- While the seconds count down, move within the area the way you will use it later, for example sitting or working at the desk.
- The positions become a zone with a dashed edge: detection zones as a polygon with at most eight corners, stay zones as a rectangle. “Done” stores it, “Restart” records again, “Cancel” ends without changing anything.
If nobody, or continuously more than one person, was detected during the learning time, no zone is created. Try again with “Restart”.
10. Settings and LED

- Installation: “Ceiling” or “Wall / corner”. A change resets all zones, the boundary and the gray area.
- Room timeout: how long presence stays reported after the area has been left. It also applies to every detection zone as long as “Timeout per zone” is off, otherwise to every zone set to “As room”.
- Sensitivity: Low mainly detects motion. High detects motion and calm presence.
- Trigger Speed: how quickly the sensor responds to people.
- Reflect horizontal: swaps right and left, for example when the presence sensor hangs turned by 180° because the power comes from above.
- LED: On shows the status continuously. Off turns the LED off 90 seconds after the start.
- LED off: a time window in which the LED stays dark, for example 22:00 to 06:30. This applies to all colors, including presence and siren. The siren itself still sounds. Identical times mean the LED is never off.
- Timeout per zone: gives every detection zone a timeout of its own (Chapter 7). Values that have been set are kept when it is switched off.
- Ghost filter: Depending on the room and mounting, the radar sometimes reports people where nobody is, so-called ghosts, for example at a window, at appliances or close beside a walking person. The filter hides them. Depending on the radar model, it learns on its own. “Learn room” and a change of the installation type delete what it has learned.
| LED color | Meaning |
|---|---|
| White | Start |
| Yellow | Reset |
| Cyan (every 10 s) | Access point / no Wi-Fi connection |
| Blue (every 10 s) | Wi-Fi connected |
| Green (every 10 s) | MQTT connected |
| Magenta | Firmware update |
| Red | Siren active |
| Pink | Presence detected |
11. Room climate and siren

Under “Environmental data” you see temperature, humidity, air pressure and brightness. After switching on, it can take at least 30 minutes until the values are correct. If needed, correct temperature, air pressure and humidity with an offset under “System”.
Siren

The built-in siren signals presence audibly, in the whole room or in a particular detection zone. You choose the trigger under “Alert”. If a zone is chosen, the siren sounds as long as the zone is occupied, that is, during its timeout too.
- With the “Siren” switch you can also switch it on and off by hand. If you switch it off while presence continues, it sounds again only with the next change.
- Under “Sound” you choose from 15 signals and melodies. Every trigger keeps its own sound, for example a gong for a zone and the two-tone horn for the room.
- Under “Listen” you play a sound as a test without storing anything.
12. Wi-Fi options

Under “More” in the Wi-Fi configuration you find:
- On / Off: Wi-Fi only at certain times. For uninterrupted Wi-Fi, set both times to the same value.
- Reconnect after: how long the presence sensor waits before it tries again after a connection loss.
- IP configuration: DHCP as delivered, a static IP address on request.
- NTP server: “pool.ntp.org” as delivered.
- Access point: Without a connection to your Wi-Fi network, the presence sensor opens its own Wi-Fi network, always at 192.168.4.1. Name and password can be set, so change the default password. With “Wifi + Access Point” it stays open in addition to the Wi-Fi connection.
All settings only take effect with “Save”.
13. Home Assistant and MQTT
The presence sensor connects either to an MQTT broker or to Senvolon remote access. Under “Connections”, choose the connection type “MQTT Broker”.

- Server and Port: name or IP address of the broker, port 1883 as delivered. With encryption (SSL/TLS) the usual port is 8883.
- Login and Password: if your broker requires a login.
- Client id: must be unique for every MQTT client.
- Main topic: the topic under which the presence sensor publishes, for example “PresenceSensor”.
- Publish interval: how often the configuration and status values, with temperature, humidity, air pressure and brightness, are sent in JSON format.
- Home Assistant: switches on MQTT discovery. Home Assistant then finds and sets up the presence sensor by itself.
All settings only take effect with “Save”.
Step by step with pictures: Integrating the presence sensor into Home Assistant. Ideas for automations: lighting control, alarm system and presence simulation on vacation with the KL MZ and Home Assistant.
Topics in the Tasmota scheme
-
tele/{Main topic}/STATE: current status as JSON, field names in lower case, for example “temperature”. Also contains “zone_names”, “zone_delay”, “zone_delay_on” and “sounds”. -
tele/{Main topic}/LWT: availability. -
stat/{Main topic}/VALUE: state of a particular value, sent on connecting and on every change and stored by the broker (retained). Boolean values “True” or “False”. -
cmnd/{Main topic}/VALUE: sets a value. Boolean values ON/OFF or TRUE/FALSE. Example:cmnd/{Main topic}/SIRENswitches the siren.
WIFI_ON, WIFI_OFF and MQTT_PUBLISH_INTERVAL are only found in STATE, they have no stat topic of their own. ZONE_DELAY_1 to ZONE_DELAY_4 only take effect while “Timeout per zone” is switched on, which is reported by stat/{Main topic}/ZONE_DELAY_ON. On stat/{Main topic}/ZONE_DELAY_n the applicable seconds are shown, so with -1 the value of DELAY.
| Value | Description |
|---|---|
| WIFI_ON | HH:MM, for example 6:00 |
| WIFI_OFF | HH:MM, for example 22:00 |
| MQTT_PUBLISH_INTERVAL | Seconds, for example 300 = 5 minutes |
| STAY_LIFECYCLE | Stay time (240 to 6000), 40 steps per second |
| DELAY | Room timeout (0 to 120 s) |
| ZONE_DELAY_1 to ZONE_DELAY_4 | Timeout of detection zone 1 to 4 in seconds (-1 = as room, 0 = no delay, 1 to 600) |
| SENSITIVITY | Sensitivity (0 = low, 1 = medium, 2 = high) |
| SPEED | Trigger speed (0 = slow, 1 = medium, 2 = fast) |
| INSTALLATION | Installation (0 = ceiling, 1 = wall / corner) |
| MIRROR | Reflect horizontal (ON/OFF) |
| LEDS | LED (ON/OFF) |
| LEDS_OFF | HH:MM, start of “LED off”, for example 22:00 |
| LEDS_ON | HH:MM, end of “LED off”, for example 6:30 |
| UPDATE | sends the current device status (STATE, PRESENCE, DETECTION, ZONES) |
| ALERT_MODE | Alert (0 = OFF, 1 = presence, 2 to 5 = zone 1 to 4) |
| SIREN | Siren (ON/OFF) |
| SOUND | Sound of the alert chosen under ALERT_MODE (0 = Standard to 14 = Fanfare). Rejected while ALERT_MODE is 0. |
| PLAY | Play a sound as a test as under “Listen”, without storing: 0 to 14. ON = sound of the chosen alert, STOP = stop. {"sound": 5, "duration": 30} repeats sound 5 for 30 s (1 to 600 s). |
| Value | Description |
|---|---|
| PRESENCE | Presence (True/False) |
| DETECTION | Number of people (0 to 4) |
| ZONES/<ZONE> | Presence per zone (True/False). Zone name in capitals, empty message for a zone without an area. |
| Value | Description |
|---|---|
| IP | IP address, for example 192.168.4.1 |
| SIGNAL | Wi-Fi reception (RSSI), for example -73 dBm |
| LWT | Availability, for example Online |
| TEMPERATURE | Temperature, for example 22 °C |
| HUMIDITY | Humidity, for example 45% |
| PRESSURE | Air pressure, for example 1010 hPa |
| BRIGHTNESS | Brightness, for example 550 lx |
| LANGUAGE | Language (EN/DE/ES) |
| VERSION | Firmware version, for example 1.0.0 / 1.26.1 |
| BOOT | Start time, for example 27.09.2025 20:53 |
| NAME | Name, for example Multi Zone Presence Sensor |
Reading over HTTP
-
http://hostname/measurementsreturns the current readings as JSON. -
http://hostname/siren?turn=onswitches the siren on,http://hostname/siren?turn=offoff. The response is the siren status as JSON.
14. Remote access and web app
With remote access you also see the readings on devices that are not on your Wi-Fi network but only on the internet. Under “Connections”, choose the connection type “Remote Access”. Access works through remote.senvolon.de. To log in you need the remote id shown there and a password of at least eight characters, which you choose yourself. If remote access cannot be reached, the presence sensor tries again regularly; you set the interval under “Reconnect after”.

As an app on the home screen
-
iPhone and iPad (Safari): Log in at
https://remote.senvolon.de. Tap the share symbol (square with an arrow pointing up, at the bottom on the iPhone, top right on the iPad), then “Add to Home Screen” and “Add”. -
Android (Chrome): Log in at
https://remote.senvolon.de. Tap the three dots at the top right, then “Add to Home screen” and “Add”.
In the web app you can switch on push messages for when presence is detected. In detail with screenshots: Monitoring the presence sensor with an app.
15. Backup, update, reset

Under “System”:
- Download configuration: saves all settings as “config.json”.
- Logging and Debug: record events and errors, the log file can be downloaded (Chapter 16).
- Sensor name on the main page and Language of the interface.
- Authentication: protects the interface with “Login” and “Password”.
- Offsets: correct temperature, air pressure and humidity upwards or downwards.
- Restart restarts the presence sensor, Reset returns it to its factory settings.
All settings only take effect with “Save”.
Loading an update and backup

Under “Update” you load new firmware or a saved “config.json”: choose the file with “Choose File”, then “Upload”. You find the current firmware under Downloads and firmware updates.
Resetting to factory settings
Without the interface, use the button: open the housing, press and hold the button “SYS” or “SW3” inside while you connect the power. Hold it for at least 5 seconds. The presence sensor is then back in its factory state.
16. If something does not work
Common requests
The interface at 192.168.4.1 does not open.
Check that your device is still connected to the Wi-Fi network “PresenceSensor-xxxxxx”, and switch off mobile data on your smartphone or tablet. Then open http://192.168.4.1/wifi.
The presence sensor cannot be reached in my Wi-Fi network or through its own Wi-Fi network.
Disconnect it briefly from the power and check the connection again.
It shows people where nobody is.
If the phantoms are behind glass, in front of a mirror or in the next room, set a boundary. If they keep appearing briefly in the room itself, switch on the “Ghost filter” under “Settings”. If they come from curtains, fans or a ventilation system, create interference zones with Learn room.
Presence goes off although someone is sitting still.
Set “Sensitivity” to high, otherwise the presence sensor mainly detects motion. Place a stay zone with a suitable stay time at the seat or sleeping place and extend the timeout if needed.
Two people are shown as one.
If they stand very close together or one hides the other from the sensor's point of view, it cannot separate them.
Someone in the room is shown in gray.
Then the boundary is too far inside at that point. Drag it outward there or teach it again (Teaching the boundary).
My zones are gone.
Changing “Installation” resets all zones, the boundary and the gray area. So set the installation before you create zones, and back up “config.json”.
Temperature or humidity are not correct.
After switching on, it can take at least 30 minutes until the values are correct. If a deviation remains, correct it with an offset under “System”.
Wi-Fi or MQTT disconnects, how do I find the cause?
Switch on logging under “System”, and “Debug” as well for even more detail. The most recent entries are shown directly below, and you can download the whole log; it is shortened automatically once it reaches a certain size. Switch both off again afterwards, which protects the internal memory. Our support will also be glad to help at support@senvolon.de, ideally with the log file.
You can find short videos on setup and operation under Video guides. Your question is not there? Write to us through the contact form.
17. Technical data
| Power supply | 5 V DC |
|---|---|
| Rated current | 1 A (power supply: 2 A to 3 A, max. 15 W) |
| Motion detection | approx. 6 m |
| Presence detection | approx. 4 m |
| People at the same time | up to 4 |
| Zones | 4 detection zones, 4 stay zones, 4 interference zones, 1 boundary |
| Beam angle | ±60° |
| Radar | 57 to 64 GHz, FMCW, max. 20 dBm EIRP |
| Wi-Fi | 2400 to 2483.5 MHz, max. 20 dBm EIRP |
| Bluetooth LE | 2402 to 2480 MHz, max. 7 dBm EIRP |
| Ambient temperature | 0 °C to 40 °C, indoors only |
| Dimensions | Ø 94 × 15 mm |
| Weight | 59 g |
18. Safety, conformity, disposal
Conformity: SENVOLON GmbH hereby declares that the radio equipment type Presence Sensor KL MZ (model SEN185 KL MZ) complies with Directive 2014/53/EU.
Radio and radar: The device contains a millimeter-wave radar for detecting presence in the 60 GHz frequency range. The radiated power is below the legally defined limits for human exposure; there is no health risk when the device is used as intended. Mount the device so that a distance of at least 20 cm to persons is maintained during operation. Modifications to the device are not permitted and void its conformity. The device is intended for indoor use only. It also contains a radio module for Wi-Fi and Bluetooth LE in the 2.4 GHz range. The two Bluetooth LE transmitters (2402 to 2480 MHz, max. 7 dBm EIRP) are not required to operate the presence sensor.
Disposal (WEEE / ElektroG): The device is marked with the symbol of the crossed-out wheeled bin and must not be disposed of with household waste. Hand it in at a collection or take-back point. Before that, delete any stored personal data such as network or user information, for example with “Reset” under “System”.
Manufacturer: SENVOLON GmbH, Dolomitstr. 37, 50226 Frechen, Germany, senvolon.de, info@senvolon.de. WEEE reg. no. DE 93352512.