Level sensor interfaces for smart home systems

All values, topics, and commands of the LiDAR and radar level sensor via MQTT and HTTP, for custom integrations into any smart home hub.

Applies to LiDAR level sensor LD and radar level sensor RD · Sensor firmware 4.2.8 and newer · As of 11/25/2026

Contents

What the sensor sends and accepts via MQTT, and what it returns via HTTP. The guides for the individual smart home systems refer to this page; current as of firmware 4.2.8.

In all examples, <Hauptthema> stands for whatever is entered on the sensor under Connections → Main topic, without the angle brackets: with main topic zisterne that gives stat/zisterne/REL_LEVEL.

Settings on the sensor

Sensor web interface → Connections:

Field Value
Connection type MQTT Broker
Server Name or IP address of the broker
Port 1883 (with encryption, usually 8883)
Login / Password only if the broker requires them
Client id unique per device; only letters, digits, _
Main topic freely selectable; we recommend only letters, digits, _
Publish interval Interval of the complete status message, factory default 5 min
Encryption TLS, if the broker requires it
Home Assistant MQTT Discovery (only for systems that understand it)

The sensor is always an MQTT client (MQTT 3.1.1). It needs a broker: either the one on your hub or one of your own (e.g., Mosquitto).

What the sensor sends

All messages are retained: anyone who connects later immediately receives the latest value.

Individual values: stat/<Hauptthema>/…

Plain text, one value per topic. Sent when the connection is established and afterward whenever the value changes.

Topic Meaning Example
stat/<Hauptthema>/REL_LEVEL Fill level in %; with tank geometry, the volume fraction; for horizontal cylinders, spheres, and tables, with one decimal place 50
stat/<Hauptthema>/LEVEL Fill height in cm 75.0
stat/<Hauptthema>/FILLING Volume in liters; without tank geometry: empty 2250.0
stat/<Hauptthema>/DISTANCE Distance sensor → surface in cm 105.0
stat/<Hauptthema>/ALERT MIN, MAX or empty (no alert) MIN
stat/<Hauptthema>/PROBLEM Sensing element returns nothing True / False
stat/<Hauptthema>/OUT_OF_RANGE Measured value outside the tank True / False
stat/<Hauptthema>/STRENGTH Signal strength of the sensing element 1200
stat/<Hauptthema>/MINI, MAXI Alert limits in % 0, 100
stat/<Hauptthema>/HYST_MIN, HYST_MAX Hysteresis in percentage points 0
stat/<Hauptthema>/ALERT_MIN, ALERT_MAX Alert switched on/off True / False
stat/<Hauptthema>/TOP2SURFACE, TOP2BOTTOM Distances full / empty in cm 30, 180
stat/<Hauptthema>/READ_INTERVAL Update interval in s 5

Peculiarities that cause integrations to fail:

  • Boolean values are written True and False (capital first letter), not true/ON/1.
  • ALERT is an empty message when there is no alert. An empty retained message deletes the stored value at the broker; some systems then keep showing the old value.
  • A measured value that is not currently available is also sent empty.
  • The temperature is not available under stat/, only in the JSON (see below).

Complete status: tele/<Hauptthema>/STATE

JSON, every Publish interval seconds and on the command UPDATE:

{"rel_level": 50, "level": 75.0, "filling": 2250.0, "distance": 105.0,
 "temperature": 12.5, "strength": 1200, "problem": false, "out_of_range": false,
 "mini": 0, "maxi": 100, "hyst_min": 0, "hyst_max": 0,
 "alert_min": true, "alert_max": true,
 "top2surface": 30, "top2bottom": 180, "read_interval": 2,
 "mqtt_publish_interval": 30, "wifi_on": "0:00", "wifi_off": "0:00",
 "powersave": false, "name": "Zisterne", "ip": "192.168.1.50", "signal": -52,
 "boot": "21.11.2026 13:16", "version": "4.2.8 / 1.21.0 (S3) - LiDAR",
 "language": "EN"}
  • In the JSON, boolean values are true JSON values (true/false).
  • alert appears only in the JSON, while an alert is active ("MIN"/"MAX"); without an alert, the field is absent. The same applies to measured values that currently do not exist.
  • signal is the Wi-Fi signal strength in dBm.
  • In the wake cycle of power saving mode, sleep is added: seconds until the next wake-up.

Availability: tele/<Hauptthema>/LWT

Online after connecting, Offline as the Last Will (keepalive 15 s) when the connection drops. In power saving mode, the sensor logs off properly before going to sleep, so it stays Online, even though it is asleep.

What the sensor accepts: cmnd/<Hauptthema>/…

Topic Value
cmnd/<Hauptthema>/UPDATE any value; immediately triggers a STATE message
cmnd/<Hauptthema>/MINI, MAXI 0…100 (%)
cmnd/<Hauptthema>/HYST_MIN, HYST_MAX 0…100 (percentage points)
cmnd/<Hauptthema>/ALERT_MIN, ALERT_MAX ON / OFF
cmnd/<Hauptthema>/TOP2SURFACE, TOP2BOTTOM LiDAR 10…1200, radar 15…4000 (cm)
cmnd/<Hauptthema>/READ_INTERVAL 1…60 (s)
cmnd/<Hauptthema>/MQTT_PUBLISH_INTERVAL 1…86400 (s)
cmnd/<Hauptthema>/WIFI_ON, WIFI_OFF HH:MM (also HH:MM:SS); the sensor rejects other values. Up to firmware 4.2.8, a plain number or ON/OFF terminated the application, and the sensor restarted
cmnd/<Hauptthema>/POWERSAVE OFF, with the retain flag

Send numbers without a unit and without decimal places. The sensor discards invalid values; for limits, hysteresis, alert switches, distances, and READ_INTERVAL it reports back the value that remains valid under stat/… (example: MINI is set to 20, MINI 150 → stat/…/MINI 20). It does not acknowledge the other commands; their value appears in the next STATE. In addition, TOP2SURFACE must be smaller than TOP2BOTTOM, and between MINI and MAXI there must be room for the hysteresis. The alert switches accept, besides ON/OFF also True/False. Commands must not be sent retained (exception: POWERSAVE), otherwise the broker repeats them on every login.

Home Assistant Discovery

With the Home Assistant switch turned on, the sensor publishes 22 entries under homeassistant/<Art>/<Client Id>_<Name>/config (retained): 11 sensor, 2 binary_sensor, 7 number, 2 switch. Systems that read the Home Assistant discovery format create the device from them on their own.

Without MQTT: HTTP

http://<IP des Sensors>/measurements returns the measured values as JSON, without a broker:

{"rel_level": 50, "level": 75.0, "filling": 2250.0, "distance": 105.0,
 "temperature": 12.5, "strength": 1200, "problem": false,
 "out_of_range": false, "alert": "-"}

Here, alert is always included, without an alert as "-". A measured value that does not currently exist also arrives as the text "-" (e.g., filling without tank geometry): anyone querying it should therefore check whether a number came back. If, on the sensor under System the Authentication switch is on, the credentials go onto the address: /measurements?login=<Login>&password=<Passwort> (or HTTP Basic Auth). Nothing can be configured via HTTP. In power saving mode, the sensor responds only while it is awake.

Verification status

Applies to sensor firmware 4.2.8 and newer.

Next steps

Manual

Level sensor LD

Mounting, connecting to Wi-Fi, setting up the tank.

Manual

Level sensor RD

Mounting, connecting to Wi-Fi, setting up the tank and radar.

Smart home

All systems

All twelve system guides at a glance.

Support

Help and contact

Phone, email, and contact form.