1. How the RD works

The level sensor RD measures the level of liquids in unpressurized containers without contact, from above, up to a container height of 40 m. It works with radar at around 80 GHz: it continuously emits modulated radio signals that are reflected by the surface, and calculates the distance from the difference between the transmitted and the received signal.

The sensor runs in your Wi-Fi network and you operate it in the browser, no app needed. The values go via MQTT to Home Assistant and other smart home systems, or via Senvolon remote access to your phone, with push notifications on alert.

More about the device on the level sensor RD product page, and an application example at Rainwater tank.

2. Before you start

You need:

  • The name and password of your Wi-Fi. The sensor uses the 2.4 GHz band.
  • A power outlet within reach of the 2 m connection cable.
  • A phone, tablet or computer with a browser.
  • For mounting, a T-shaped spirit level and, depending on the installation location, a mounting bracket.

Safety instructions:

  • The sensor is intended solely for the purpose described in these instructions.
  • The sensor is supplied ready to plug in. Plug it only into a properly installed socket outlet and protect the plug and the socket outlet from moisture.
  • Disconnect the mains plug before cleaning or maintenance. Do not use the sensor if the cable, the plug or the enclosure is damaged.
  • Do not open or modify the device. Do not expose it to direct sunlight and use it only in the environment specified in the technical data.
  • Not for tanks containing flammable liquids such as heating oil, diesel or gasoline.
  • Keep a minimum distance of 20 cm from persons during operation.

3. Mounting

  1. At the top of the tank, as centrally as possible. The sensor measures down onto the surface from above. Keep a distance of at least 15 cm from the highest fill. You enter the exact distance later under “Tank Config”.
  2. Stable and level in both directions. Align the sensor with a T-shaped spirit level in the longitudinal and transverse direction. Mounted at an angle, it measures incorrectly or not at all.
  3. As little as possible in the radar cone. The radar beams downward in a cone of ±25°, and the cone becomes wider with distance. Objects such as pipes or hoses should interfere with it as little as possible. In difficult installation situations, adapt the radar to its surroundings, see Adapting the radar to the tank.
  4. Fasten it. With enough distance from the inner wall. The sensor must never be immersed in the liquid.
  5. Connect the power. Plug the mains plug (230 V) into the socket outlet. For the version with an external antenna, connect the antenna first, see Chapter 4.

T-shaped spirit level for aligning in the longitudinal and transverse direction.

Drilling pattern and dimensions: Technical data. A suitable accessory is the mounting bracket. If the sensor delivers unstable or wrong values after mounting, adapt the radar to its surroundings, see Chapter 13.

4. Antenna and reception

Wi-Fi in the shaft: on the left the integrated antenna when the Wi-Fi reaches the tank well; on the right an external antenna over the manhole cover for a tank buried in the ground.

Make sure the installation location has a sufficiently strong Wi-Fi connection. After setup, you can see it as RSSI on the main page under “More”:

RSSI Wi-Fi signal quality
above -50 dBm excellent
-50 to -60 dBm good
-60 to -70 dBm adequate
below -70 dBm weak

With external antenna (SEN180-EA): Place the antenna where reception is good, for example above the manhole cover, and screw the plug onto the RP-SMA connector. Only connect the antenna when the sensor is disconnected from the power. Only antennas with 2400 to 2483.5 MHz, 50 Ω, VSWR of at most 3.0, linear polarization, a gain of at most 3.5 dBi and an RP-SMA connector are permitted. Suitable are our external Wi-Fi antenna and the extension cable.

More on this: Ensuring Wi-Fi reception for the level sensor.

5. Connecting to Wi-Fi

  1. Connect to the sensor. After you plug it in, the sensor opens its own Wi-Fi network called “LevelSensor-xxxxxx”. Connect your phone, tablet or computer to it; the factory password is “12345678”.
  2. Open the setup page. In the browser, enter http://192.168.4.1/wifi. If the page does not appear, check whether you are still connected to the sensor’s Wi-Fi and turn off mobile data on your phone or tablet.
  3. Enter your Wi-Fi. Select your Wi-Fi under “Available networks” or enter the name yourself under “Network name (SSID)”, plus the password. Under “Hostname”, give the sensor a name of at most 15 characters, for example zisterne. You can leave everything under “More” as it is. Tap “Save” and wait a moment.
  4. Check the connection. If it worked, the IP address and the status “connected” are shown at the bottom of the page. Note down the address.
  5. Back to your own Wi-Fi. Connect your device to your Wi-Fi again and open the IP address in the browser. If your router supports names, you can also use http://zisterne, on a FRITZ!Box http://zisterne.fritz.box.

Wifi configuration: available networks, network name MeinWLAN, password, hostname fuellstand, below that IP 192.168.178.47 and status connected.

Forgot the address? It is listed in the device list of your router, or you can search for the sensor’s name with a network scanner app. If it can be found neither in your Wi-Fi nor as “LevelSensor”, briefly disconnect it from the power.

6. Setting up the tank

Under “Tank Config” you tell the sensor where full and empty are. Measure both values from the sensor downward:

  • Distance to surface: Distance to the surface when the tank is full, at least 15 cm.
  • Distance to bottom: Distance to the bottom or to the lowest level you use, at most 4,000 cm.

Liters instead of just percent

Tank shapes to choose from: cuboid, vertical cylinder, horizontal cylinder and sphere; for other shapes a custom capacity table.

Under “Tank geometry”, choose cuboid, vertical or horizontal cylinder or sphere and enter the length a and, if applicable, b in cm. What a and b are is shown by the graphic on the page. For a horizontal cylinder, b must not be smaller than the usable height (distance to bottom minus distance to surface).

Tank configuration: distance to surface 30 cm, distance to bottom 130 cm, tank geometry horizontal cylinder, length a 300 cm, length b 100 cm.

Other shape: capacity table

For other shapes, choose the “Capacity table” under “Tank geometry”; you can usually get it from the tank manufacturer. It assigns the contents in liters to each filling level. The table is built up from bottom to top: at the bottom there is always “0” and “0” for the empty tank, at the top the full filling level with the full contents. The filling levels must increase upward and must not exceed the usable height. Add rows with “+” and delete them with “-”.

Capacity table: filling levels 0, 25, 50, 75, 100 cm with 0, 461, 1178, 1896, 2356 liters, plus and minus buttons.

For advanced users: formulas instead of liters

In the “Filling volume” column, formulas are also allowed. The height within a section is called h, and each section calculates with its own height. This is how you combine shapes from bottom to top, for example a vertical cylinder (radius R, height a) with a truncated cone on top (height b, upper radius r):

Sketch: vertical cylinder with radius R and height a, with a truncated cone on top with height b and upper radius r, filling height h.

Level (cm) Filling volume (l) / Formula
a + b =pi/3*h*(R**2+R*(R-h/b*(R-r))+(R-h/b*(R-r))**2)/1000
a =pi*R**2*h/1000
0 0

Insert your values in cm for a, b, R and r. Divided by 1,000 this gives liters. Allowed are + - * / ( ) **, sqrt(), exp(), log() (natural logarithm), sin() asin() cos() acos() tan() atan() in radians, abs() and pi.

How often values are updated

Set it with the “Update” slider on the main page under “More”, between 1 and 60 seconds. This applies to display, alert and MQTT; measuring is continuous anyway. On a computer, set the slider roughly with the mouse and precisely with the arrow keys. All settings only take effect after “Save”.

7. Alert at MIN and MAX

Main page under More: switches Alert MIN and Alert MAX, minimum 10 %, maximum 90 %, Hyst min and Hyst max 5 pp each, Update 10 s, Sensor signal 45 dB, RSSI -52 dBm.

On the main page under “More”, use the sliders to set a minimum and a maximum in percent. With the switches “Alert MIN” and “Alert MAX” you decide whether an alert is raised there at all. If the level reaches or falls below the minimum, or reaches or exceeds the maximum, the sensor reports “MIN” or “MAX”. The display turns red: with MAX the part of the bar above the maximum, with MIN the whole bar.

Main page with active alert MAX in red: filling 99.1 %, bar above the maximum red.

To keep the alert from flickering, there is the hysteresis (“Hyst min”, “Hyst max”, in percentage points). With it you control when the alert is cleared again. This keeps the alert signal stable in the event of frequent fluctuations, and you can, for example, control a pump for filling or pumping out up to a certain level.

The minimum must be at least 2 percentage points below the maximum, and each hysteresis at least 2 percentage points smaller than the gap between the two. The sliders do not allow invalid values. An alert that is switched off is not shown.

The alert is not an overfill prevention device within the meaning of WHG and AwSV.

The alert reaches your phone as a push notification via remote access or goes to your smart home via MQTT. An example: Dry-run protection for the garden pump.

8. Measured values and messages

  • Level: Relative level in percent
  • Fluid: Filling volume in liters
  • Distance: from the sensor to the surface in cm
  • Height: Absolute level in cm
  • Alert: MIN or MAX
  • Enclosure: Temperature inside the enclosure in °C
  • Sensor signal under “More”: strength of the radar signal in dB
  • RSSI under “More”: Wi-Fi reception in dBm
Display Meaning What to do
“Sensor issue!” The sensor is not receiving any valid measured values. Check the alignment, do not cover the radar surface with metal, films or enclosure parts, then look at the echo image.
“Measurement outside the range!” The distance is outside the distances set under “Tank Config”. Check the distances, for example after an overfill.
“-” instead of measured values No valid measured value yet since switching on or restarting. Wait a moment.

Overheating protection: If the enclosure reaches 65 °C, for example in strong sunlight, the sensor switches itself off and starts up again below 55 °C. During that time it cannot be reached and reports neither measured values nor alerts. If it cannot measure the enclosure temperature several times, it shows “-” there.

9. Remote access and push

With remote access you can see the level anywhere and receive push notifications on alert. The sensor uses either remote access or MQTT.

Connections with connection type Remote Access: Remote id, password, Reconnect after 30 sec.

  1. Switch it on. Under “Connections”, choose “Remote Access”. Note down the “Remote id” shown; it always begins with a small “L”. Set a password of at least 8 characters and save. If remote access is not reachable, the sensor tries again regularly; you set the interval under “Reconnect after”.
  2. Log in. Open remote.senvolon.de on your phone, on the iPhone in Safari, on Android in Chrome, and log in with the Id and password.
  3. Add it as an app. iPhone and iPad: share icon (square with an arrow pointing up, at the bottom on the iPhone, top right on the iPad), “Add to Home Screen”, “Add”. Android: menu (three dots at the top right), “Add to Home screen”, “Add”.
  4. Switch on push. In the web app, you switch on the notifications for alerts.

In detail with screenshots: Querying the level via app.

10. Home Assistant and MQTT

Connections with MQTT Broker: Server, Port 1883, Reconnect after, login, password, Client id, Main topic, Publish interval 5 min, Encryption, Home Assistant.

  1. Enter the broker. Under “Connections”, choose “MQTT Broker”, enter the name or IP address under “Server” and the port under “Port” (default 1883), and if needed login and password. “Reconnect after” defines when a new attempt starts.
  2. Assign names. “Client id” and “Main topic” only from letters without umlauts, digits and “_”, without “+”, “#” and “/”. The Client id must be unique for each MQTT client, and the Main topic must be filled in.
  3. Tick Home Assistant. Home Assistant then finds the sensor by itself via MQTT Discovery. Besides the measured values, it creates the minimum, maximum, both hysteresis values, Update, both distances and both alert switches as adjustable values.

For an encrypted connection, use the “Encryption” switch (SSL/TLS), then the TLS port of your broker, usually 8883. The “Publish interval” defines how often the complete status is sent as JSON. All settings only take effect after “Save”.

Step by step with pictures: Integrating the level sensor into Home Assistant. For Homematic: Rainwater tank level in Homematic. Ideas: Rainwater tank dashboard with rain forecast and Rainwater tank as rain retention.

For ioBroker, Loxone, openHAB, Homematic, KNX and other systems there is a separate guide for each: Level sensor in the smart home.

Topics, values and commands

The sensor uses the Tasmota scheme. If a measured value changes, it is sent with the next refresh (“Update” slider) under stat/{Main topic}/…. The publish interval applies to the complete status under tele/{Main topic}/STATE.

  • tele/{Main topic}/STATE: current status
  • tele/{Main topic}/LWT: availability
  • stat/{Main topic}/VALUE: state of a value
  • cmnd/{Main topic}/VALUE: sets a value, for example cmnd/{Main topic}/WIFI_ON for a new time

Send numbers without a unit (for example “20”), times as HH:MM, and the alert switches with ON or OFF. The sensor discards invalid values. For distances, minimum, maximum, hysteresis, Update and alert switches, it then returns the valid value under stat/…. The distance to the surface must be smaller than the distance to the bottom: if both increase, send TOP2BOTTOM first; if both decrease, send TOP2SURFACE first.

Configuration values and commands
Value Description
WIFI_ON HH:MM, for example 6:00
WIFI_OFF HH:MM, for example 22:00
MQTT_PUBLISH_INTERVAL Publish interval in seconds, for example 300 = 5 minutes
TOP2SURFACE Distance to surface, for example 20 cm
TOP2BOTTOM Distance to bottom, for example 200 cm
READ_INTERVAL Refresh interval for the measured values, for example 5 s
UPDATE sends the current device status
MINI Minimum, for example 10 %
MAXI Maximum, for example 90 %
HYST_MIN Hysteresis minimum in percentage points
HYST_MAX Hysteresis maximum in percentage points
ALERT_MIN Alert minimum, ON or OFF
ALERT_MAX Alert maximum, ON or OFF
POWERSAVE Switch off power saving mode: OFF, send with retain flag
Measured values
Value Description
DISTANCE Distance to surface, for example 25 cm
LEVEL Absolute level, for example 120 cm
REL_LEVEL Relative level, for example 85 %
FILLING Filling volume in liters, for example 50 l
ALERT Alert: MIN, MAX or empty
STRENGTH Strength of the radar signal, for example 20 dB
TEMPERATURE Enclosure temperature, for example 20 °C
Status
Value Description
IP IP address, for example 192.168.178.47
SIGNAL Wi-Fi reception (RSSI), for example -73 dBm
PROBLEM technical problem with the sensor (True/False)
OUT_OF_RANGE measured value outside the setting (True/False)
LWT Availability, for example Online
SLEEP Seconds until wake-up (power saving mode)

Retrieval via HTTP

http://hostname/measurements returns the current measured values as JSON. With access protection, append the credentials: http://hostname/measurements?login=…&password=…

11. Power saving mode

With the “Power saving” switch under “System”, the sensor goes into deep sleep and wakes up only at fixed intervals: it measures, sends the values to the MQTT broker or remote access, and goes back to sleep. You choose the interval under “Wake up every” (1 to 24 hours). The mode can only be switched on when the sensor is connected to your Wi-Fi and to an MQTT broker or remote access.

  • Maintenance window: After switching on and after every restart, the sensor stays awake and reachable for as long as set under “Maintenance window” (5 to 60 minutes). Every page request extends it, including retrieval via HTTP. As long as the main page or “Wifi”, “Connections” or “System” is open, even in a background tab, the sensor does not go to sleep. So after setup, close all pages of the web interface and do not query the values via HTTP at regular intervals.
  • While asleep the sensor can be reached neither via your Wi-Fi nor via its own Wi-Fi. To wake it up, briefly disconnect it from the power. In the following maintenance window you can switch the mode off, via MQTT with POWERSAVE OFF.
  • Alerts are evaluated at every wake-up. If a limit is exceeded or fallen below between two wake-ups, the sensor only notices it at the next wake-up.
  • If it cannot connect when waking up, it goes back to sleep after one minute at the latest and tries again next time. The Wi-Fi time control is suspended in power saving mode.

12. Smoothing, calibrating, protecting

System menu: download configuration and log file, Logging, Debug, Sensor name, Language, Moving median, Window size 15 s, Confirm large changes after 10 s, Power saving, Wake up every 1 h, Maintenance window 10 min, Authentication, buttons Calibration, Restart and Reset.

Smoothing unstable values

Under “System”, the “Moving median” smooths out outliers, for example caused by waves or reflections. The “Window size” states over how many of the most recent measured values the median is formed. Since about one value is produced every second, 60 s is roughly the last 60 seconds. Example: 100, 101, 100, 145 and 99 cm become 100 cm, and the outlier 145 drops out. The larger the window, the calmer the values.

“Confirm large changes after” (10 s by default): if the value jumps by 10 cm or more, it must stay stable for that long before it is displayed. Smaller jumps from 3 cm upward get through after a few measurements. More on this: Eliminating fluctuating measured values and outliers.

Calibrating

Calibration: table with Measured and Target in cm with the rows 100 to 110, 50 to 55 and 0 to 0, buttons plus, minus, Back, Save and RADAR Configuration.

With clear liquids such as water, or if the installation is not exactly vertical, a calibration is worthwhile: “System”, “Calibration”. Under “Measured (cm)”, enter the displayed distance and under “Target (cm)” the distance you measured by hand. If there is only one row, the sensor shifts all distances by the same difference. Further measuring points above the row “0”/“0” are converted linearly in between. The table is built up from bottom to top, so begin with the smallest distance.

If it has already been calibrated, reset the table to a single row “0”/“0” before a new calibration and save, otherwise the correction is applied twice. More on this: Calibrating the level sensor.

Protecting access

Under “System”, the “Authentication” switch turns on login and password for the interface: only letters without umlauts, digits and - . _ ~, with a password of at least 8 characters.

Time-controlled Wi-Fi and further options

Wifi configuration with the More section open: Access point SSID and password, Wifi + Access Point, On and Off, Reconnect after, IP configuration DHCP, NTP server pool.ntp.org.

  • On / Off: Wi-Fi only at certain times, in German local time. Identical start and end times mean: always on. This requires internet for the time (NTP server, “pool.ntp.org” by default).
  • Reconnect after: how long the sensor waits after a dropout before the next attempt.
  • IP configuration: DHCP by default, with a static IP address on request.
  • Access point: Without a connection to your Wi-Fi, the sensor opens its own Wi-Fi, always at 192.168.4.1. With “Wifi + Access Point” it additionally stays open; this is switched on by default. Change its password after setup (at least 8 characters).

13. Adapting the radar to the tank

The radar receives not only the echo of the surface, but also echoes from everything that is fixed in the tank: walls, brackets, pipes, fittings. If needed, for example with unreliable measured values, the “RADAR Configuration” page shows you what the radar currently sees. You open it under “System”, “Calibration” with the “RADAR Configuration” button.

RADAR Configuration: echo image with a clear peak at 0.55 m, reported distance 0.550 m, signal 45 dB, below it search mode Peak, sensitivity 10, transmit power 0, switches Clutter filter and Learn clutter, buttons Back, Save and Read spectrum.

Reading the echo image

  • Horizontally is the distance from the sensor in meters, vertically the strength of the echo as a value without a unit. The higher the deflection, the stronger the echo at that distance.
  • Blue is the current echo, gray are the learned clutter echoes. The green dashed line shows the distance the sensor is currently reporting, the dot the strongest peak.
  • Under “View” you switch between the full echo image and the cleaned one, in which the fixed clutter echoes have already been subtracted.
  • “Read spectrum” reloads the echo image at any time.

Filtering out clutter echoes

With “Learn clutter”, the sensor takes a snapshot of the fixed echoes and stores it as the clutter image. If the “Clutter filter” is on, it subtracts this image from the current signal. In the best case, only the surface, which moves, remains. Here is how:

  1. Check the echo image. Read the spectrum. If the surface is a clear single peak, you are done. If there are further clear peaks, the clutter filter is worthwhile.
  2. Empty the tank or lower the level considerably, if possible. Then the surface does not disturb the clutter image.
  3. Learn. Switch on “Learn clutter” and save. After that, the clutter filter is on automatically.
  4. Check. Refill the tank and check that the reported distance is stable and the signal is above 10 dB.

Learn the clutter image preferably when the container is empty or the level is low. As long as there is no suitable clutter image, leave the clutter filter off. A “contaminated” clutter image degrades the measurement.

Search mode, sensitivity, transmit power

  • Search mode: “Peak” reports the strongest echo, the right choice for a clear surface. “Threshold” reports the first echo above the detection threshold, useful when not the strongest but the nearest echo counts.
  • Sensitivity: Smaller values make the sensor more sensitive. It then also detects weak or distant surfaces, but is more likely to pick up interference. Set a smaller value if the surface is detected too weakly, a larger one if clutter echoes show up as the surface.
  • Transmit power: Smaller values mean more power, good for long distances or weakly reflecting surfaces. Larger values mean less power, helpful when close, strongly reflecting parts overdrive the signal, and the radiated emission is reduced.

All settings only take effect after “Save”. A reset under “System” only switches off the clutter filter on this page. Search mode, sensitivity and transmit power stay as they are. Switch the clutter filter back on if needed.

14. Backup, update, reset

  • Backup: Under “System”, you download the configuration as JSON. It contains your credentials, so keep it confidential.
  • Firmware update: Download the file from Downloads and firmware updates, do not rename it, and upload it under “Update” via “File upload” and “Upload”. Wait until the main page appears again.
  • Restore a configuration: Upload the saved “config.json” in the same way, then “Restart”. Only then does it take effect.
  • Sensor name and language: Under “System”, you change the name on the main page and in Home Assistant, and the language of the interface (German, English or Spanish).
  • Reset: After a confirmation prompt, it restores everything to the factory state and deletes the log. After that, the sensor can be reached again via its own Wi-Fi “LevelSensor”, and the interface is in English. Of the radar configuration, the reset only switches off the clutter filter, see Chapter 13.

Update menu: File upload with Choose file, buttons Back, Upload and Restart.

15. If something does not work

Common concerns

Reception

Weak Wi-Fi in the rainwater tank

Read the signal strength and improve reception, with or without an external antenna.

Alert

Alert triggers too often

With hysteresis, the alert stays stable during fluctuations.

Remote access

Remote access and push

Remote id, login at remote.senvolon.de and push notifications on alert.

I cannot find the “LevelSensor” Wi-Fi.

Briefly disconnect the sensor from the power. Without a connection to your Wi-Fi, it opens its own Wi-Fi; with “Wifi + Access Point” (on by default) it also stays open while a connection exists. If it is connected to your Wi-Fi, you can also find it in the device list of your router. In power saving mode, it cannot be reached at all between wake-ups.

The page 192.168.4.1 does not open.

Check whether your device is still connected to “LevelSensor” and turn off mobile data on your phone or tablet. Then open http://192.168.4.1/wifi.

The connection keeps dropping.

Read the RSSI under “More”. Below -70 dBm, reception is weak. An external antenna on the SEN180-EA helps, see chapter Antenna and reception.

The values jump.

Check that the sensor points straight down, and read out the echo image. If it shows further relevant peaks besides the surface, the clutter filter is worthwhile, see Filtering out clutter echoes. After that, the “Moving median” under “System” helps.

“Sensor issue!” is shown on the main page.

The sensor is not receiving any valid measured values. Check the alignment. The radar surface must not be covered by metal, films or enclosure parts.

The sensor is temporarily unreachable.

If power saving mode is on, it sleeps between wake-ups. In strong sunlight, it switches itself off at 65 °C in the enclosure and starts up again below 55 °C. Also check whether a time window is set under “More” in the Wi-Fi configuration.

How do I find the cause of a problem?

Switch on logging under “System”, and for more details also “Debug”. The latest entries appear directly below, and you can download the whole log. From 100 KB on, the sensor shortens it by removing the oldest entries. In everyday use, switch both off again. Our support will also gladly help at support@senvolon.de, ideally with the log file.

You can find short videos on setup and operation under Video instructions. Your question is not there? Write to us via the contact form.

16. Technical data

Feature SEN180 SEN180-EA
Measuring principle Radar, 77 to 81 GHz, at most 20 dBm EIRP
Beam angle ±25°
Measuring range 0.15 to 40 m
Accuracy ±5 mm
Resolution 1 mm
Antenna internal, 1.16 dBi external, RP-SMA, at most 3.5 dBi
Wi-Fi 2400 to 2483.5 MHz, at most 20 dBm EIRP
Power supply 230 V AC, protection class II
Power consumption max. 2 W
Degree of protection IP65
Temperature range -20 to +40 °C
Dimensions (W × H × D) 55 × 39 × 108 mm
Weight 115 g
Connection cable 2 m

Drilling pattern from above: mounting holes with 6 mm diameter, spacing 92 mm and 35 mm, enclosure 108 × 55 × 39 mm.

17. Safety, conformity, disposal

Conformity: Hereby, SENVOLON GmbH declares that the radio equipment type SEN180 / SEN180-EA is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at senvolon.de.

Radio and radar: The device contains a millimeter-wave radar for level measurement in the frequency range around 80 GHz. The radiated power is below the statutory limits for human exposure; when the device is used as intended, there is no health hazard. Make sure that the radar surface is not covered by metal, films or enclosure parts. Modifications to the device are not permitted and void the radio approval. In addition, the device contains a radio module for Wi-Fi in the 2.4 GHz range (technical data).

Disposal (WEEE / ElektroG): The device bears the symbol of the crossed-out wheeled bin and must not be disposed of with household waste. Hand it in at a collection or take-back point. Delete stored personal data such as network or user information beforehand, for example with “Reset” under “System”.

Manufacturer: SENVOLON GmbH, Dolomitstr. 37, 50226 Frechen, senvolon.de, info@senvolon.de. WEEE Reg. No. DE 93352512.